[Top] [Prev] [Next] [Bottom]

Index         


Numerics

 10Base2 port 2-13
 10BaseT port 2-11
 5ESS D-4

A

 airflow and cooling 2-2
 applying power 2-14
 AUI port 2-12

B

 BNC port 2-13
boot
 failure A-7
 sequence A-5
boot messages
 checking A-5
 interpreting A-6

C

cables
 category 5 twisted pair for the S/T interface pinout B-14
 category 5 twisted pair for the U interface pinout B-14
 high-density 10-pin for the U interface pinout B-15
 high-density 50-Pin pinout B-7
 high-density 68-pin pinout B-4
 male-to-male null modem pinout B-2
 male-to-male straight-through pinout B-3
 RS-232 pinout B-10
 RS-530 pinout B-13
 specifications B-1
 V.35 pinout B-11
 X.21 pinout B-12
 chassis accessibility 2-2
 command line interface 1-6
 ComOS software 1-5
connecting
 10Base2 2-13
 10Base5 2-12
 10BaseT 2-11
 console 2-7
 T1/E1 2-9
 contact information xiv
 mailing lists xiv
 technical support xiii
 conventions in this guide xii
 cooling and airflow 2-2

D

 DB-15 female connector 2-12
 diagnostic mode, diagnostic messages A-6
DIP switch
 position for console use 2-8
 position for Ethernet 10Base2 connection 2-13
 position for Ethernet 10BaseT connection 2-11
 position for Ethernet AUI connection 2-12
 position for external modem installation 3-2
 DMS-100 D-6
 document conventions xii
 documentation, related ix

E

E1
 line connection 2-9
 environmental requirements 2-2, C-2
 equipment required 2-3
Ethernet
cable specifications  Ethernet B-16

 interface specifications B-16
Ethernet cable, connecting
 10Base2 2-13
 10BaseT 2-11
 AUI 2-12
expansion boards
 general information 1-2
 installing 3-6
 removing 3-10
 external modems, installation 3-1

F

 fuse, replacing A-7

G

 grounding requirement for Ethernet 10Base2 port 2-13

I

installation
 checklist 2-1
 expansion boards 3-6
 external modems 3-1
 fuse A-7
 memory 3-3
 IP address, setting 2-16
 IPX address, setting 2-17
ISDN BRI
 long-distance carrier D-7
 ordering service D-1
 site wiring D-7
ISDN PRI
 line connection 2-9

L

LED behavior
 observing for troubleshooting A-1
login
 password 2-16
 procedure 2-16

M

 mailing lists, subscribing to xiv
memory
 adding memory 3-3
 specifications 3-3
messages on the console
 checking A-5
 interpreting A-6

N

network address
 IP 2-16
 IPX 2-17
network connections
 Ethernet 10Base2 2-13
 Ethernet 10BaseT 2-11
 Ethernet AUI 2-12
 T1/E1 2-9

O

 ordering ISDN BRI D-1
 site wiring D-7
 switch type D-4, D-6

P

 password 2-16
 PC settings for console use 2-8
pinouts
 category 5 twisted pair cable for the S/T interface B-14
 category 5 twisted pair cable for the U interface B-14
 high-density 10-pin cable for the U interface B-15
 high-density 50-Pin cable B-7
 high-density 68-pin cable B-4
 male-to-male null modem cable B-2
 male-to-male straight-through cable B-3
 RS-232 cable B-10
 RS-530 cable B-13
 V.35 cable B-11
 X.21 cable B-12
 PMconsole 1-6
 PortMaster software 1-5
ports
 by PortMaster model 1-3
 Ethernet 10Base2 2-13
 Ethernet 10BaseT 2-11
 Ethernet AUI 2-12
 T1/E1 2-9
power
 applying 2-14
 guidelines 2-2

R

 rack installation 2-5, 2-6
 references x
 RFCs x
 related documentation ix
 replacing fuse A-7
RJ-48C connector
 for Ethernet 10BaseT port 2-11

S

 safety recommendations 2-3
SIMM
 installing 3-3, 3-6, 3-10
 specifications 3-3
   single inline memory module. See SIMM
site requirements
 air flow and cooling 2-2
 chassis accessibility 2-2
 environment 2-2
 power guidelines 2-2
 wiring for ISDN BRI D-7
 software, PortMaster 1-5
specifications
 cables B-1
 electrical C-2
 environmental C-2
 interface C-1
 physical C-2
 SIMM 3-3

T

T1
 line connection 2-9
T1 lines
 connecting 2-9
 terminal settings for console uset 2-8
 thin Ethernet. See 10Base2 port
 troubleshooting A-1

W

work area
 required equipment 2-3
 safety recommendations 2-3


[Top] [Prev] [Next] [Bottom]

spider@livingston.com
Copyright © 1998, Lucent Technologies. All rights reserved.