I'm in US-West land, my switch is a DMS-100, I was running
CT1s to my portmasters (much less expensive than PRIs).
I received an excessive amount of "Port Error - Unknown State"
along with the spontaneous dropped call. At the rate of about
1 every 5 minutes. We tried everything with Lucent, they
tried everything (short of sending someone out). But nothing
could fix it.
We recently switched to all PRIs, not one "Port Error - Unknown State"
yet (been running for a week).
My lesson learned? If you're in US-West land on a DMS-100 switch,
don't order CT1s for your Lucent Portmasters. :)
-Mike
-- Michael Wilkinson CacheNET SysAdmin michael@cache.net +1 (435) 787-4009 - To unsubscribe, email 'majordomo@livingston.com' with 'unsubscribe portmaster-users' in the body of the message. Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>