Once upon a time Ana Paula Sabelli shaped the electrons to say...
>I need to know how to configure Caller-Id in my users File.
If this is Lucent RADIUS, then this is not a valid Attribute. If this
is some other version of RADIUS, then I'd check with that vendor.
>wsagarra Auth-Type = System, Caller-Id = 2214231623
> Service-Type = Framed-User,
> Framed-Protocol = PPP,
> Port-Limit = 1
There are two related Attributes in Lucent RADIUS:
Called-Station-Id - this is the number the user dialed.
Calling-Station-Id - this is the number the user is calling from.
I presume you mean the latter in 'Caller-Id', so it would be:
wsagarra Auth-Type = System, Calling-Station-Id = "2214231623"
Service-Type = Framed-User,
Framed-Protocol = PPP,
Port-Limit = 1
-MZ
-- -=*X GOT CLUE? ISPF II - SAN DIEGO, CA 3/6-10 <URL:http://www.ispf.com/> X*=- <URL:mailto:megazone@megazone.org> Gweep, Discordian, Author, Engineer, me.. Join ISP/C Internet Service Providers' Consortium <URL:http://www.ispc.org/> "A little nonsense now and then, is relished by the wisest men" 781-788-0130 <URL:http://www.megazone.org/> <URL:http://www.gweep.net/> Hail Discordia! - To unsubscribe, email 'majordomo@livingston.com' with 'unsubscribe portmaster-users' in the body of the message. Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>