(PM) RE: Stuck PM3 ports

Erik P. Power (erik@sitespecific.net)
Mon, 15 Feb 1999 14:43:11 -0800

Oh, I just noticed that there are 2 multi-link interfaces that won't seem to
go away--ptp51 and ptp52. These are not bound to any active ports.

-----Original Message-----
From: Erik P. Power [mailto:erik@sitespecific.net]
Sent: Monday, February 15, 1999 2:37 PM
To: Portmaster-Users
Subject: Stuck PM3 ports

I've got a confusing problem, and I'm hoping someone has seen this before
and can shed some light on it. I have a customer dialing ISDN DOV to my PM3,
and after he disconnects, the port(s) he was connected to still show him as
using those ports. Pinging the IP addresses of the "dead" ports shows he
has, indeed, disconnected. If I manually reset the ports in question, the
ports show themselves available again. Otherwise, I have to wait 15 to 20
minutes for the ports to clear. Something really strange, though--PMVision
shows the ports are clear and available, but a query of OID 1.3.6.1.2.1.2.1
(iso(1).org(3).dod(6).internet(1).mgmt(2).mib-2(1).interfaces(2).ifNumber(1)
) shows that more ports are in use than are currently being reported by
PMVision. Note that a "sh ses" from the command line produces the same
results as PMVision. What's the story? Are these "phantom in-use" ports
really used? I haven't had enough load on the PM3 to be able to determine if
people are getting busies due to this problem, but I'm concerned. Input
welcome...

______________________________________________________

Erik P. Power Site Specific, Inc.
erik@sitespecific.net 1402 3rd Ave. Suite 324
Voice: (206) 652-0677 Seattle, WA 98101
Fax: (206) 652-0676 http://www.sitespecific.net
______________________________________________________

-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.