Re: (PM) PRI/PM3 Probs

Thomas Kinnen (tkinnen@livingston.com)
Sun, 14 Feb 1999 10:31:37 -0800

RichardC wrote:

[Sending back to mail list]

> Line0 shows fine. We only have one PRI for now. Debugged all the ISDN tests
> and all we're fine. JUst get a Fast Busy when attempting to call in!

A fast busy is a telco issue 99% of the time. When I was in FL if I
rebooted the PM more then three times in a row or was down for more then
3 min the telco would automatically busy out the trunk at their end and
unless they checked the switch directly their test would show the line
active.

If there are any * in the 'show line0'/'show line1' then you are in an
alarm condition.

----
Thomas C Kinnen - <tkinnen@livingston.com> <tkinnen@ra.lucent.com>
"All of the opinions stated above are my own and not my employer's,
unless they were given to me by my employer"
-