Re: (PM) PRI Problems

John Nowack (john@tremont.dpc.net)
Sun, 24 May 1998 00:04:35 -0500

>The switch type is set to DMS-100 and this has been verified with Sprint to
>be the correct switch type. Sprint is complaining about not seeing any
>framing coming from my equipment, but I thought the telco was supposed to
>provide framing and that was why the Portmaster is showing yellow alarms
>(loss of frame). Sprint is also saying that the timing on the line is
>slipping and want me to verify I am deriving timing from their line. As far
I just went through a similiar problem with GTE during a changeover from
CT1 to PRI. Seems they forgot to re-option the fiber cards between the
two switches from D4-AMI to ESF-B8ZS. Frequent alarms on the T1 and
the telco could not see the D channel even though the PM showed it up.

If you are running through multiple switches have the telco check each
segment of the T1 and visually check the optioning of the cards.

John

--