(PM) Can't get high_water option to drop lines

Nicky Smith (nicky@netmcr.com)
Sat, 23 May 1998 23:35:07 -0400

I have a customer with a PM-2i-U running ComOS v3.7.
The customer has 2 BRI lines connected to it and wants
to keep a single 64K channel up 24x7 and use the high_water
option to pickup additional 64K channels when there is high
demand. He is connecting to our PM3 running ComOS 3.7.2c3.
When it first connects, within a few seconds the remaining
3 channels connect also. There is never much activity
but all channels never show any idle time thus never drop.

Now the problem... How do I get the extra three 64K channels
to drop off when usage is low?

Nicky Smith
mailto:nicky@netmcr.com
-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.