Tell your rep to check with Pamela Meyer/Patti Silva regarding Livingston
equipment...
On Tue, 27 Jan 1998, Livingston maillists address wrote:
> We've had a PM3 installed since December and all has worked well with
> analog calls ...
>
> Now GTE has finally upgraded a bunch of 1920 era rotary COs with DMS100s,
> giving many here (Big Island of Hawaii) BRI capability.
>
> The problem is that when a ISDN data call is made to our PM3, we see the
> D channel call setup but nada comes over the Bearer channel and the client
> finally times out with a "no PPP active" message ....
-- Aloha from Paradise,Sherwood