(PM) ISDN Calls (fwd)

MegaZone (megazone@livingston.com)
Sun, 25 Jan 1998 18:41:01 -0800 (PST)

Once upon a time David Sovereen shaped the electrons to say...
>I have yet to get an ISDN call to successfully come into our PM-3's.
>
>Right now, we are trying to get Ascend Pipelines (50s, 75s, and 130s) to
>connect in. But it just isn't working.

Try dialing out of the PM-3 back into itself. If that works that you
can be fairly confident the PRI is ok.

>If I telnet in and watch the connection, I will see the username pop up in
>a "show sessions" screen, but the status is always "DISCONNECTING". If I
>do a "show s#", I will see DISCONNECTING and it will say "Protocol Error".

There was a protocol error - either in the ISDN or PPP. I'd recommend
running a PPP debug - 'set console' 'set debug 0x51' - then dial in.
You can run the results through the PPP Decoder Ring on the Debug Tools
page on our website.

>I don't know if this is a PM issue, or a RADIUS issue. There are no
>entries in the RADIUS accounting log.

The debug should show if it is even getting to the point of authentication.
But I doubt that it is with a protocol error termination.

>I assume that ISDN users can be authenticated from the RADIUS server,
>correct? Do I need any special configuration to do this?

yes and no.

>Also, what are Directory Numbers? Do I need to configure those?

The phone numbers for the PRI, or each DS0. And no, they aren't needed
on PRIs.

-MZ

--
Lucent Remote Access Division - Chair, Department of Interstitial Affairs
Phone: 800-458-9966 510-737-2100 FAX: 510-737-2110 megazone@livingston.com
For support requests: support@livingston.com  <http://www.livingston.com/> 
Snail mail: 4464 Willow Road, Pleasanton, CA 94588
-