> This question involves a PM3 w/K56flex modems on an AMI/D4 CT1 connected to
> a GTD-5 switch in GTE land:
>
> I've been having some of my lines go out-of-service for some unexplained
> reason the past few days. The last time it has happened, I asked the GTE
> tech for more information about what is happening. He said he was getting
> the following error messages on his end:
>
> Inband sending error detected.
> Time out awaiting start dial.
> Trunk failed tone test.
Have GTE option their switch to send you zero digits.
Make sure that both the PM3 and the switch are set for "wink" signalling.
-- Jay Hennigan jay@west.net --
WestNet: Internet service to Santa Barbara, Ventura and the world.
805-892-2133 805-289-1000 805-578-2121
-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.