Mark Costlow wrote:
> What I'm looking for are some ways to get more detailed debug info about the
> CT1 signal. Or, information about "line padding" switch parameters. I found
> some recommended settings for the DMS-100 in the list archives, but didn't see
> any specific info about 5ESS switches. Has anyone been through that before
> with a 5ESS?
I have done this, but it is specific to U S WEST. We standardized the
way we provision CT1's in 5ESS switches, so our "setting" is actually
several other settings all bundled together under one command.
In other words, you just ask for X and the switch knows to adjust
several different things at the same time.
-- Kyle Platts Network Engineer !NTERPRISE Networking Services U S WEST Communications --------------A6F549622D1733DF016F51F0 Content-Type: text/x-vcard; charset=us-ascii; name="vcard.vcf" Content-Transfer-Encoding: 7bit Content-Description: Card for Kyle Platts Content-Disposition: attachment; filename="vcard.vcf"begin: vcard fn: Kyle Platts n: Platts;Kyle org: !NTERPRISE Networking Services adr;dom: 600 Stinson Blvd;;2 South;Minneapolis;MN;55413; email;internet: kwplat1@netmail6.uswc.uswest.com title: Network Engineer tel;work: (612) 664-3234 tel;fax: (612) 664-4774 x-mozilla-cpt: ;0 x-mozilla-html: FALSE version: 2.1 end: vcard
--------------A6F549622D1733DF016F51F0--