Also even if it is a clear channel T1, you will still only be able to
move 56k through it (per channel).
JS
JB wrote:
>
> In order to connect to a PM3 which has a channelized T1 plugged into it,
> with a isdn modem/router, your modem/router will need to support "DATA OVER
> VOICE". Unless you plug a PRI into the PM3, which will accept normal ISDN
> calls. Most ISDN modems/routers these days support "DATA OVER VOICE". I
> know the Netopia routers work just fine in "DATA OVER VOICE" mode but I'm
> not sure if the Pipline 50 supports it. Using "DATA OVER VOICE" will
> connect the user at 56 KB per channel (you can connect at 2 b's) /vs 64 KB
> per channel when using PRI's.
>
> Try a differnent ISDN modem that support "DATA OVER VOICE" for testing...
-
To unsubscribe, email 'majordomo@livingston.com' with