It appears the '123-7856' number needs to be troubleshot. What kind of
router are you dialing into from the OR-U?
Set max ports to 1 and leave off the other #. If it doesn't connect...
>Is there a way that I can reconfigure my OR-U so that it uses both channel
>in bonded mode when the numbers are different (my old ISDN router allowed me
>to do that) ?
>
Well, we don't do "bonding" - its MLPPP - and it occurs automatically (when
the location is set to 'multilink on', only if the destination IP address of
the device being dialed is the same for both links and that it supports MLPPP.
Hope this helps,
Tom Fellenz
/
Techical Support Engineering / L I V I N G S T O N
4464 Willow Road /___ Enterprises, Inc.
Pleasanton, CA 94588 (800)458-9966
http://www.livingston.com support@livingston.com
-