I'm using a Tielink ONS 150 CSU/DSU, 128k fractional T1. Telco
says they can see my CSU fine, and the CSU says it's getting sync
from the remote unit.
On the router, I did the "set s1 protocol frame" and the router
doesn't complain, but when I "show all" it says it's clocked at
56k. Telco says they don't see frames coming from the router.
The backpanel switch for S1 is definitely set to V.35. I'm running
the latest release of ComOS for the 211, 3.2 I think it is ?
Different numbering than for the portmasters.
Am I missing some undocumented steps here ? I'm starting to think
I've got a bad cable or bad port.
Here is some pertinant listings:
Command> show s1
----------------------- Current Status - Port S1
---------------------------
Status: CONNECTING
Input: 0 Abort Errors: 0
Output: 89375 CRC Errors: 0
Pending: 0 Overrun Errors: 0
TX Errors: 0 Frame Errors: 0
Active Configuration Default Configuration
-------------------- ---------------------
Port Type: Netwrk Netwrk (Hardwired)
Line Speed: Ext Clock Ext Clock
Modem Control: on on
Local Address: a.b.c.70 a.b.c.70
Netmask: 255.255.255.0 255.255.255.0
Interface: Unassigned (FRM,Quiet) (FRM,Quiet)
Mtu: 1500 0
LMI Poll Int: 10 (seconds)
DLCI List:
Command> show all
Local Addr: x.y.z.129
Gateway: a.b.c.16 Netmask:
255.255.255.128
DNS Server: some.dns.server Domain:
some.domain.com
Port Speed Mdm Host Type Status Input
Output Pend
---- ----- --- ---------------- ------ ------------- ----------
---------- ----
S0 9600 off Login USERNAME 0
28 0
S1 56000 on Netwrk CONNECTING 0
89388 0