....... snip .........
> I suspect strongly that this coincides with the fact that three of my
> BRIs are having some kind of problem whereas they show NO-SERVICE but
.... snip ...
Yes I've seen this. The PM2 behaves badly when confronted with errors on
the BRI circuits. And a reboot is the only way to correct it. Typical
design engineer behavior: "But the BRI circuits are supposed to follow The
Spec!".
Regards,
Al Hopper Logical Approach Inc, Plano, TX. al@logical-approach.com
Voice: 972-379-2133 Fax: 972-379-2134
For a Good Time (TM), checkout: www.retards.com
-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.