Re: (PM) "set lineX loopback" command

Tim Moloney (moloney@netsrq.com)
Thu, 23 Jul 1998 08:42:05 -0400 (EDT)

On 23-Jul-98 Jon Lewis wrote:

>On Wed, 22 Jul 1998, Tim Moloney wrote:
>
>> Last Friday I converted my dialin lines from channelized T1 to PRI. I
>> unplugged the cable from the channelize T1 wall jack and reconfigured
>> the PM-3 using the following commands.
>>
>> set isdn-switch ni-2
>
>You changed the switch type. That in itself requires a reboot...does it
>not? The line may have shown up as looped, because the PM3 was still
>trying to talk to it as a CT1.

I didn't know that. What happened makes a little more sense now.
Is that documented anywhere? I didn't see anything in the Command
Line Administrators Guide.

Now what exactly does the "set lineX loopback" command do since it
doesn't appear to put lineX in loopback, even after the reboot. It
also is not documented in the Command Line Administrators Guide
however I realize that my Guide is older than the ComOS that I'm
running (3.8b15).

_____ ___ ___ ___
(_ _)( )( \/ ) Tim Moloney Think of something
) ( ) ( ) ( moloney@netsrq.com witty and imagine it
(___) (___)(__)\/(__) Sarasota, Florida was written here.
-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.