(PM) OR-U problem

Irve Towers (irvet@knight-hub.com)
Wed, 22 Jul 1998 18:56:58 -0400

OR-U ComOS 3.7.2L
Client using Pipeline-50
Cannot connect second B-channel.

S1 connects at 64Kbps just fine
S2 connects but immediately posts the following debug info.

Confirming Connect - 64Kbps / Data (b2 ref:d)
DISCONNECT_ACK inavlid state 3
DISCONNECT_ACK
CALL_CLEAR

I assume inavlid is Lucent-eeze for invalid (:-})

Can someone suggest where to look for this? Both ends can call and connect
from either B-channel to it's other B-channel. Telco is of course saying
"It's just fine".
TIA
Digitally yours,
Irve Towers
The Hub Internet Services - Washington DC - http://www.knight-hub.com/
Alternate e-mail -> support@knight-hub.com -> webmaster@knight-hub.com
-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.
Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>