Re: (PM) Connection type acct vs. snmp vs. show

Josh Richards (josh@lucent.com)
Fri, 10 Jul 1998 19:55:37 -0700 (PDT)

On 2 Jul 1998, Paul C. Diem wrote:

> We're seeing some discrepencies on modem connection types (protocol and
> compression). For example, for one caller, the radius accounting start record
> shows:
>
> Connect-Info = "2400 MNP/NONE"
>
> yet, snmp returns:
>
> ...livingstonSerialModemProtocol.4 = none(1)
> ...livingstonSerialModemCompression.4 = none(1)
>
> and a show m25 on the pm3 displays:
>
> Connection Type: DIRECT/NONE
>
> and finally, the radius accounting stop record shows:
>
> Connect-Info = "2400 MNP/NONE"
>
> This is with ComOS 3.7.2c3. So far, I've only noticed it with 2400bps
> connections.

Interesting. Have you opened a ticket with support to get this resolved?

-jr

----
Josh Richards - <jrichard@livingston.com> - <josh@lucent.com>
[Beta Engineer] - LUCENT Technologies - Remote Access Business Unit
<URL:http://www.livingston.com/> * <URL:http://www.lucent.com/dns/>

-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.
Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>