Re: (PM) Disconnections with b15 and b17

Josh Richards (jrichard@livingston.com)
Tue, 30 Jun 1998 15:32:44 -0700 (PDT)

On 27 Jun 1998, Steve Siopsis wrote:

> We were running b15 since it came out. Everything was really stable and
> V90 was working great. A week ago we installed a new PM3 and moved the
> old one to another location. We connected the new PM3 to the same PRI,
> with the same software version and configuration. Since then almost
> nobody is able to get a stable connection, and there are many retrains
> and renegotiations. V90 conenctions which were fine for almost 2 months
> (since b15 came out), disconnect in 5 to 10 minutes. With debug on, all
[..]

What do the lineX stats look like on the PRIs coming into the PM-3? Do a
"show line0" and "show line1".

-jr

----
Josh Richards - <jrichard@livingston.com> - <josh@lucent.com>
[Beta Engineer] - LUCENT Technologies - Remote Access Business Unit
<URL:http://www.livingston.com/> * <URL:http://www.lucent.com/dns/>

-