Re: (PM) PPP Negotiation Fails Over BRI

Stephen Zedalis (tintype@exis.net)
Tue, 30 Jun 1998 16:47:06 -0400 (EDT)

Mark,
I think I've seen this a couple times with BA. The CONNECT
messages come in via the D channel because they are talking and trying to
setup the channels, but there are no B channels to pass the LCP REQUESTS
(But the D channels "think" there are B channels to hand off to, and
report them IDLE vice NO SERVICE) . You might want to check whether you
actually have B channel connectivity at both ends. One thing that I
usually do in this case is to attach to each of the S1 and S2 ports and
try an ATDT <phone number at other end>. If you get your login: prompt
then there is nothing wrong with the lines. You might also want to give
Mike Jonas a call at BA.

Take Care

Stephen Zedalis
System Administrator - Exis Net, Inc.

On Tue, 30 Jun 1998, Mark Borchers wrote:

>Have been watching debugging at both ends throughout this case:
> OR-U calls
> PM-2 records a CONNECT
> OR-U tries to send LCP REQUESTS
> PM-2 never receives LCP REQUESTS
> OR-U gives up and hangs up
> PM-2 reports normal CALL CLEAR

-
To unsubscribe, email 'majordomo@livingston.com' with