The errors indicate problems on the PRI - and the fact that the problem
follows the line is the kicker - you have a problem on the PRI. If you
can more the line around and wherever you use it it has the same problems,
you should be able to force BA to address it.
>---------------------- line0 - T1 Primary Rate ISDN ---------------
> Status: UP Framing: ESF Encoding: B8ZS PCM: u-law
> Receive Level: -15dB to -22.5dB
This receive level is very low. +2 to -7.5 is great, -7.5 to -15 is ok,
I don't like to see a level this low. Next is "less than -22.5", which
means off the scale. Perhaps this line is at the extreme low end of this
range.
-MZ
-- <URL:mailto:megazone@megazone.org> Gweep, Discordian, Author, Engineer, me.. Join ISP/C Internet Service Providers' Consortium <URL:http://www.ispc.org/> "A little nonsense now and then, is relished by the wisest men" 781-788-0130 <URL:http://www.gweep.net/> <URL:http://www.megazone.org/> Hail Discordia! - To unsubscribe, email 'majordomo@livingston.com' with 'unsubscribe portmaster-users' in the body of the message. Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>