(PM) Disconnections with b15 and b17

Steve Siopsis (livin@gatekeeper.vic.com)
Sat, 27 Jun 1998 14:42:27 -0400 (EDT)

We were running b15 since it came out. Everything was really stable and
V90 was working great. A week ago we installed a new PM3 and moved the
old one to another location. We connected the new PM3 to the same PRI,
with the same software version and configuration. Since then almost
nobody is able to get a stable connection, and there are many retrains
and renegotiations. V90 conenctions which were fine for almost 2 months
(since b15 came out), disconnect in 5 to 10 minutes. With debug on, all
we get is:

Session Terminated - User Request - Call Circuit Closed

or

Session Terminated - Lost Carrier

This happens with every single modem but V90 modems just disconnect
faster. Also most K56 flex connections which connect at 46000 slow down
eventually to reach 14000 or even lower.The old PM3 still has no problems
at the new location like it didn't have on this site. Everything is of a
5ESS switch (PRI lines). b17 made everything even worse plus the !@
problem. Licent support hasn't been able to help up to now. Anybody has
any thoughts on this?

Thanks!
Steve
VIC

-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.
Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>