Steve Bourne wrote:
>
> The telco always provides the T1 clocking. If no telco (i.e.: direct,
> cross-over cable) you will need a T1 WAN card, which can supply clocking

This is a pretty broad statement, and incorrect. If anything, the telco
never provides timing. When a telco DOES provide timing, it is actually
coming from their terminating equipment on the circuit, ie voice switch,
frame switch. When you order a point to point connection, the timing
should be totally transparent and it is your responsibility for overall
timing of the circuit.

-- 