Once upon a time Pete Baumgartner shaped the electrons to say...
>Perhaps someone on this group might be able to help me out. I have 3
>Portmaster 3's all running Com OS version 3.8b13 and I cannot get any of
>them to sync up to the PRI lines I had Sprint install. The units are
>optioned for ISDN, b8zs and ESF and a show line0 shows that the line is
>up and the receive level is between +2.5 and -7.5Db, but all the

Switch type. What is your switch type? I've seen this many times when
that was set incorrectly. And don't rely on the physical type - a DMS-100
could be NI-1 signalling.

Can you send the list a 'show line0'?

-MZ

-- 
<URL:mailto:megazone@megazone.org> Gweep, author, webmaster, human being, me
"A little nonsense now and then, is relished by the wisest men" 781-788-0130
<URL:mailto:megazone@gweep.net> <URL:http://www.megazone.org/> Hail Discordia!
-