Re: (PM) Max Telnet Sessions

Chris Conn (cconn@abacom.com)
Thu, 14 May 1998 15:25:26 -0400 (EDT)

On Thu, 14 May 1998, Scott Carpenter wrote:

> At 11:03 AM 5/14/98 -0700, Timothy A. Gregory wrote:
> >Anyone know what the max number of
> >telnet sessions is on PM3s and 25s?
> Is there a way
> >to bump it up, or to set a timeout for inactivity in case
> >a telnet session hangs?
> No

What you can do however is (and this is assuming you still have access via
telnet or some other form) do a "show netc" and "reset netc xxx" where xxx
is a hung telnet session...this will clear out that connection and allow
you to use it again.