Re: (PM) Users getting dumped

John Nowack (john@tremont.dpc.net)
Wed, 13 May 1998 23:01:38 -0500

>For the last two weeks, our PM-3 users have been getting dumped, just about
>every morning at between 8:30AM /8:45AM When they dial back on they get a
>busy signal for the next 4-5 minutes and then everything is O.K. The PM-3
>is not rebooting.
>
>I have had GTE technicians all over it and they claim they don't see any
>evidence of the PRI going out. GTE has put a continuous monitor on it and
>each time, their log has been empty.

What kind of switch? I have seen one instance on a Siemens switch where
some kind of diagnostics that were run on the switch in the middle of the
night one day a week made a PM3 (connected to CT1) flake out with a
constant alarm condition and loss of sync until power cycled. The switch
showed no alarms and all error logs were empty. Stopped the diagnostics
and no more PM3 flake-outs.