Re: (PM) PM3 PRI Questions

Marcus Vogt (marcus@wizard.teksupport.net.au)
Fri, 6 Feb 1998 12:31:52 +1100 (EST)

G'day,

>We have a PM3 with 60 modems and 2 PRI lines. I am seeing the following
>errors on the PRI lines.

>Do I need to worry about these ?

> E-bit 3683
> E-bit 32316

When we had bursts of these (~3000 E-bit errors at a time) it would hang up
all our dialins. We logged a fault call with the supplier of the PRI's.
They put the equipment on test and when we reported it a second time they
had all the logs to chase it up. We have had no further problems with
this.

The only other thing that changed was the upgrade to 3.7.2c3 - if you have
not done so already, I'd advise upgrading to this as it fixed almost all
of the modem compatability issues we were having.

Yours,

Marcus Vogt
Computer Systems Engineer

Teksupport Pty. Ltd.
7 Warwick Avenue,
Springvale, Email marcus@teksupport.net.au
Melbourne 3171 Phone +61-3-9562-4577
Victoria Australia World Wide Web http://www.teksupport.net.au/
*************************************************************************
-