Re: (PM) Win 3.1 problems after 3.7.2c3

Stephen Zedalis (tintype@exis.net)
Fri, 30 Jan 1998 13:29:46 -0500 (EST)

On Fri, 30 Jan 1998, Brian Elfert wrote:

>On Thu, 29 Jan 1998, Tom wrote:
>
>> The SLIP implementation is no longer tolerent of misconfigured MTU
>> sizes. The MTU size on both sides must now match. Trumpet Winsock
>> defaults to 1500, and PM3 (PM2 is different!) only goes up to 1006.
>
>Hasn't SLIP always been limited to a MTU of 1006? I thought only PPP
>could go to 1500?
>We've always had the MTU for SLIP in our users file set to 1006. Not that
>we have more thatn 1 or 2 customers who use SLIP.

I thought so myself.

Not to mention, how hard is it to change Trumpet to 1006? Not!

With over 4000 customers, we have less than 5 with SLIP anyway. (Old
Atari machines, Amiga machines, etc)

-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.