> On Thu, 29 Jan 1998, Tom wrote:
>
> > The SLIP implementation is no longer tolerent of misconfigured MTU
> > sizes. The MTU size on both sides must now match. Trumpet Winsock
> > defaults to 1500, and PM3 (PM2 is different!) only goes up to 1006.
>
> Hasn't SLIP always been limited to a MTU of 1006? I thought only PPP
> could go to 1500?
It has no limit, except those imposed by a particularly implementation.
Nearly everbody uses 1500 for all p2p frame types because it avoids
fragmentation to and from ethernet.
> Brian
Tom
-