Re: (PM) BRI Bonding problem

Josh Richards (jrichard@livingston.com)
Wed, 14 Jan 1998 15:08:23 -0800 (PST)

On Tue, 13 Jan 1998, Rick Wagner wrote:

> I have a PM2 with ISDN mod card in it. I have an ISDN hunt group
> I run COMOS version 3.7 4 megs Ram
>
> I have a customer that can dial one channel and get connected just fine but
> he cant get two channels bonded.
> He gets one channel just fine on either channel. He as both of the
> following pieces of equipment which work when he calls another provider but
> they dont bond when he calls me. Any tips..
>
> Ascend pipeline 25px and 3Com
> OfficeConnect Lan Modem (3C892)?
>

What does his RADIUS entry look like? Make you sure you do not have
Port-Limit set.

>
> Thanks
> Rick Wagner

---
Josh Richards - <jrichard@livingston.com>
Beta Engineer 
Lucent Technologies (Remote Access Business Unit)
(previously Livingston Enterprises, Inc.) 

- To unsubscribe, email 'majordomo@livingston.com' with 'unsubscribe portmaster-users' in the body of the message.