Re: (PM) Multilink ISDN Failing (fwd)
Mark Morley (mark@islandnet.com)
Tue, 13 Jan 1998 13:52:21 -0800 (PST)
> Once upon a time Mark Morley shaped the electrons to say...
> > Livingston Portmaster, which do not allow simultaneous connections within
> > 500 milliseconds of one another.
> > The reason Windows 95 clients can connect to the Livingston Portmaster and
> > Windows NT clients fail is because Windows NT 4.0 tries to connect both
>
> Right. And we found and fixed this is ComOS 3.7.2. In both our testing and
> those customers who had originally reported the problem, 3.7.2 fixed it.
> You can bring up both channels simultaneously in 3.7.2 and they'll bond.
>
> If this is happening under 3.7.2 (You never did say your version) then I
> don't believe it is the same thing.
Yes, we are using 3.7.2 (I assume this is still the latest version).
> No known problems.
Any ideas what else it may be then?
Mark
-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.