Remember this is CT1, and not PRI.
> you are getting a lot of BPV's, and it is going in and out of yellow.
>
> Don't say anything else.
>
They already knew.
Here is the latest info. I rebooted the box a while ago, and it now
shows:
Command> show line1
---------------------- line1 - T1 Inband DS0 ---------------
Status: UP Framing: D4 Encoding: AMI PCM: u-law
Signaling: Trunk E&M immediate start
Receive Level: +2dB to -7.5dB
Alarms Violations
----------------------------- -----------------------------
Blue 0 Bipolar 98269
Yellow 6 CRC Errors 3433
Receive Carrier Loss 0 Multiframe Sync 524
Loss of Sync 4
Command> version
Livingston PortMaster PM-3 ComOS 3.7.2
System uptime is 3 hours 33 minutes
Can the Bipolar violations seem to jump up dramatically every once in a
while. It keeps going up, but it is not a steady count. I can check
it 3 or 4 times within 5 minutes and it will never change. Come back
30 minutes later and it has increased a lot. What do bipolar violations
indicate? Would that (or any of these other errors) correlate to
individual users getting dropped? I've been told that the yellow alarms
will cause ALL users to get dropped at the same time.
-- Eric Calvert Caveland Connection http://www.caveland.net - To unsubscribe, email 'majordomo@livingston.com' with 'unsubscribe portmaster-users' in the body of the message.