> 1. A 2 T1 unit can use a max of 49 IPs - 24 per T1 plus C0 if it has a
> network mode set. This changes depending on line config. I believe
> if both T1s are set for PRI and C0 isn't network then the pool will be
> 46. A 2 T1 unit should not, to my knowledge, use 60. That would be a
> 2 E1 unit.
>
> 2. The command to manually set it is 'set pool #'.
The reason I asked... I have the PM3 with 48 modem and a single PRI. I
expected a maximum of 48 addresses to be used and assigned the IP range to
start at 206.76.17.211. Once, when I checked the PM3 with a show sessions
I had a user at 206.76.17.254 and one time when *I* connected I was given
206.76.18.1! This really confused me...therefore, my question. I have
limited the pool size to 46 and that SHOULD fix the problem...
---------------------------------------------------------------------
| Tim Winders, CNE | Email: twinders@SPC.cc.tx.us |
| Network Administrator | Phone: 806-894-9611 x 2369 |
| South Plains College | Fax: 806-897-4711 |
---------------------------------------------------------------------
-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.