Re: (PM) Provisioning PRI
Karl Denninger (karl@Mcs.Net)
Tue, 6 Jan 1998 11:29:35 -0600
On Tue, Jan 06, 1998 at 12:24:03PM -0500, Zak Wolfinger wrote:
> I have a PRI on order from Ameritech. However I'm not sure that our
> Ameritech rep has provisioned the line correctly for our Livingscent <grin>
> PM3. I tried calling Livingston's Provisioning Center but the lady I spoke
> with said that they couldn't tell me what the correct provisioning is, they
> can only order the line for me. I asked her if when they order the line for
> me, do they tell Ameritech how to provision it. She said yes they do, but
> she couldn't tell me how to provision it. Duh!
>
> Can anyone tell me what the correct provisioning would be on a PRI from
> Ameritech for our PM3?
>
> Zak Wolfinger - zak@cyberlink.com
> Systems Administrator - CyberLink, Inc.
> (219) 235-1400, (219) 674-8279
ESF Framing, B8ZS Coding on the physical circuit.
ISDN control NI-2 or AT&T Custom (depending on the switch you're connected to)
Pass either 4 or 7 digits for DNIS (your choice; I set up for 7)
--
--
Karl Denninger (karl@MCS.Net)| MCSNet - Serving Chicagoland and Wisconsin
http://www.mcs.net/ | T1's from $600 monthly to FULL DS-3 Service
| NEW! K56Flex support on ALL modems
Voice: [+1 312 803-MCS1 x219]| EXCLUSIVE NEW FEATURE ON ALL PERSONAL ACCOUNTS
Fax: [+1 312 803-4929] | *SPAMBLOCK* Technology now included at no cost
-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.