Re: (PM) Double Login (fwd)

MegaZone (megazone@livingston.com)
Sat, 22 Nov 1997 01:13:06 -0800 (PST)

Once upon a time Brian Elfert shaped the electrons to say...
>> Does it mean it is impossible to detect double login in using livingstone
>> PM3-radius system? What a bad news :(
>Which Radius product supports this?

The only one I feel does it acceptably today is Cistron RADIUS. There
are other servers out that attempt it, but they all rely on RADIUS alone
and the RADIUS protocol has loopholes since it wasn't designed for this.

I've ranted about this many times here and on -radius, so I'm sure you can
find that in the archives.

And this should shift over to portmaster-radius.

-MZ

--
Livingston Enterprises - Chair, Department of Interstitial Affairs
Phone: 800-458-9966 510-737-2100 FAX: 510-737-2110 megazone@livingston.com
For support requests: support@livingston.com  <http://www.livingston.com/> 
Snail mail: 4464 Willow Road, Pleasanton, CA 94588
-
To unsubscribe, email 'majordomo@livingston.com' with