Re: (PM) Diff betw T1-Span & Ethernet Cables?

Mark Radabaugh (mark@woodville.net)
Sat, 15 Nov 1997 22:42:58 -0500

Went down in the basement and looked... The last Sprint guy out here stuck a
3' piece of flat satin in the line from the smartjack to the jack my PM-3 is
plugged into. Didn't realize it was there till now. It seems to be working
OK though.

Mark
mark @ woodville.net

-----Original Message-----
From: Jon Lewis <jlewis@inorganic5.fdt.net>
To: Jake Messinger <jake@ams.com>
Cc: Stephen Fisher <lithium@cia-g.com>; PM Mailing List
<pmlist@cosmo.mitec.net>; portmaster-users@livingston.com
<portmaster-users@livingston.com>
Date: Saturday, November 15, 1997 10:36 PM
Subject: Re: (PM) Diff betw T1-Span & Ethernet Cables?

>On Sat, 15 Nov 1997, Jake Messinger wrote:
>
>> Id put T1=4 R1=5 and T2=3 and R2=6 and use Non twisted flat
>> cable, and things were fine. This was for 9.6 sync leased lines..
>
>I've seen providers like Sprint use flat satin CAT2 wire for connecting
>CSU's to T1 smartjacks...and have seen 2 pair satin (regular phone cable)
>used for 10baseT ethernet over short runs. Both work. I wouldn't do
>either if I had better options available..
>
>------------------------------------------------------------------
> Jon Lewis <jlewis@fdt.net> | Unsolicited commercial e-mail will
> Network Administrator | be proof-read for $199/message..
> Florida Digital Turnpike |
>______http://inorganic5.fdt.net/~jlewis/pgp for PGP public key____
>
>-
>To unsubscribe, email 'majordomo@livingston.com' with
>'unsubscribe portmaster-users' in the body of the message..
>
>
>

-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.