Re: Big Problem need solved

Miguel Correia Lima (liv@luc.triang.com.br)
Sun, 10 Aug 1997 18:31:30 -0300 (EST)

Hi Jack,

Thanks by your replay.

On Sun, 10 Aug 1997, Jake Messinger wrote:
> On Sat, 9 Aug 1997, Miguel Correia Lima wrote:
> > When I purchase the last expantion (3o card) of PM2-eR
> > only the first 20 ports complitely a ppp negociation, the
> > last 10 ports receice a call, connect, radius delivery
> > autorization, but the connection do not estabilished,
> > pmconsole show CONNECTING continuos.....
>
> Open the box and check the REVISION on the 10 port card. Look on or near
> the tag with the bar code on it. It should be revision B or C. A will not
> work in a 2eR.

OK! 400-1240 Rev B!

> Also check to make sure the dual jumpers are in the right location.
+---+ midles jumpers closed with 2 jumpers.
o|o o|
o|o o|
+---+
1 2

--------------------------------
Miguel Correia Lima - Tech. Dep.
Triangulo Internet Provider
Fone/Fax: +55-34-216-4251