Re: IRX 211 and Frame Relay

Arnaud Girsch (girsch@marben.com)
Sat, 25 Nov 1995 22:16:57 -0800 (PST)

> > Active Configuration Default Configuration
> > -------------------- ---------------------
> > Port Type: Netwrk Netwrk (Hardwired)
> > Line Speed: Ext Clock Ext Clock
> > Modem Control: on on
> > Local Address: a.b.c.70 a.b.c.70
> > Netmask: 255.255.255.0 255.255.255.0
> > Interface: Unassigned (FRM,Quiet) (FRM,Quiet)
> > Mtu: 1500 0
> > LMI Poll Int: 10 (seconds)
> > DLCI List:
>
> if it is frame, should you not have a dlci??
Yup, it should ...
If the LMI poll time is wrong (has to be the same at both sides !), then
it won't get any DLCI ...
Mine is set to 5 sec.

> also my interface shows
> Interface: frmW1 (FRM,Routing) (FRM,Routing)
Yup .. it's also weird, I think, that the interface is unassigned ...

> you can do a
> set s1 speed 128000 I think
If my understanding is correct, for a Frame on fractional T1, the speed
should always be 56k ... and then the CSU/DSU has to be configured to
have several 56k channels.
I was told that even for a full T1, it has to be 56k.

hum .. I also have "Modem Control" set to off ... don't know if it really
makes a difference.

Arnaud.

-- 