Re: How Many frame connections can a 2eR take?

Patrick Greenwell (patrick@value.net)
Fri, 13 Oct 1995 08:35:31 -0700 (PDT)

On Fri, 13 Oct 1995, Baha Baydar wrote:

> I seem to recall seeing that the W1 port on the 2eR can take 2 incoming
> PVC's. Is this correct? Or can more than that b routed through?
>
> The reason I ask is that we would like to bring 3 Frame Relay connections
> from remote POP's into one W1 port.
>
> Thanks in advance for any help.
>
> --
> Baha Baydar Sales and Support
> internet service and information systems
> bbaydar@ra.isisnet.com (902) 429-isis

Yup. We have three on ours right now. I think you need at least COMOS
3.1.3 to do the sub-interfaces.

Patrick