Troubleshooting A Modem Connection To A Lucent PortMaster ® 3 And PortMaster 4Perform the following tasks to troubleshoot a modem dial in user who is having trouble connecting to a Lucent PortMaster® 3 or PortMaster 4:
Follow these instructions for each modem having trouble dialing in to the Lucent PortMaster 3 or 4. Lucent InterNetworking Systems Technical Support handles every modem problem as a separate issue on separate trouble tickets. This information is required to minimize delays in finding a solution. Task 1: Check The Modem Hardware.Perform this task if you have a PortMaster 3 and the problem at the customer site can be described as excessive retrains or excessive failures to connect on dial in. In August 1998, the InterNetworking Systems of Lucent Technologies announced a hardware recall and replacement of certain 56Kbps 8-port or 10-port modem boards on the PortMaster 3. The board must meet BOTH revision and date code criteria to be part of the replacement program:
Task 2: Verify The Lucent ComOS® Version.Make sure the PortMaster is running the latest version of Lucent ComOs® by checking http://www.ra.lucent.com/forms/one-click-dnload.cgi. Download the latest ComOS version, if necessary. If you are upgrading a PortMaster and the customer is running the Microsoft Windows 95 or Windows 98 operating system and using a Rockwell HCF modem, see http://www.ra.lucent.com/tech/bulletin/comos-modem.html for more information. Task 3: Check The T1 Line Condition.Perform this task if the problem at the customer site can be described as excessive retrains or excessive failures to connect on dial in. Do the following to check the channelized T1 or ISDN PRI line condition:
Task 4: Upgrade The Customer Modem Firmware.Contact the dial in user with the problem modem and work with that person to resolve the problem. Upgrade the modem to the latest firmware to resolve known problems. The modem must be running the latest V.90 software released by the modem manufacturer. If the customer has a problem connecting, try the following procedures:
Read the following sections for details and websites on common modem manufactures. LT Win Modem
For technical support for Lucent LT Win Modem, call 1-800-372-2447. COMPAQ HCF 3Com/U.S. Robotics (USR) Acer HCF Diamond SupraExpress K56flex Modems Task 5: Test The Customer Modem.Step 1: Test modem dialing end-to-end: The "first mile" is the local loop between the customer and their telephone company central office. The "last mile" is the local loop between the PortMaster and its local telecommunications service provider. The service provider is in the middle. Ask the customer to test the first mile, service provider, and last mile by dialing in to your PortMaster . If the customer displays low connection speeds or disconnects while dialing in, proceed to Step 2: Test the first and last mile. Step 2: Test the first and last mile: Ask the customer to dial in to the PortMaster using a long distance code. For example: 1010321-1-950-555-1212. By dialing 1010321, you are forcing the call through a different telephone switch, (the long distance telephone switch). If the connection speeds do not change when the customer dials through the long distance switch, continue to Step 3: Test the first mile only. If the customer is connecting at higher speeds with the long distance carrier, the problem is with the local service provider. The customer must inform their local telephone company that they can connect properly through a different switch, but the line conditions are preventing them from connecting through the local switch at higher speeds. The following are examples of other long distance carrier codes:
Note: These codes are for United States customers only and might not work in Canada, Australia, New Zealand, and South America. Ask non U.S. customers to check with an operator for a long distance code option. If your customer dials other long distance carrier codes and the telephone call does not go through, their local switch is not configured to allow these types of calls. Continue to Step 3: Test the first mile only. Step 3: Test the first mile only: Ask the customer to do the following:
Note: A customer using an X2-only modem cannot get better than a V.34 connection to a PortMaster even if he or she appears to connect at 56Kbps to the USR test site. X2 is a proprietary protocol, and 56Kbps line diagnostics are not modem dependent. A V.34 modem will also incorrectly show a 56Kbps connection to the USR test site. Task 6: Check Ethernet Collisions.Perform this task if the problem at the customer site can be described as slow or poor throughput on dial in. Check your collision domain by observing the collision lights, or network interface statistics. A rule of thumb is not to have more than two PortMaster 3's on the same collision domain.
Task 7: Receive Additional Support.If you are still having modem problems that need to be addressed, go on to Modem Information Sheet for the PortMaster 3 and 4 (seen below). Recommended Reading Modem Information Sheet For The Lucent PortMaster ® 3 and 4Collect the following information about your PortMaster 3 or 4 the modem, and the modem user to help your technical support engineer solve the problem. The best way to isolate a modem dial in problem is for the Lucent InterNetworking Systems Technical Support team to treat modems from different manufacturers and models as separate trouble issues on separate trouble tickets. Step 1. Collect PortMaster Information:
Step 2. Collect Dialing Customer Information:
Do other customers dialing in with the same modems have the same problem? If so, explain briefly. In addition, use HyperTerminal terminal emulation software to collect the following information from the modem:
Step 3. Report The Information. Email the information you have gathered to your technical support engineer. Enter your ticket number in the subject header. A Level 3 technician will contact you either by telephone or email. The technician will log in to your PortMaster to run diagnostics to get additional information for further analysis. This information is necessary to enable Lucent InterNetworking Systems to identify and resolve the problem in a timely manner. Thank you for your cooperation. Recommended Reading (c) 1999 Lucent Technologies. All rights reserved. PortMaster®, ComOS®, and ChoiceNet® are registered trademarks of Lucent Technologies, Inc. RADIUS ABM®, PMVision®, IRX®, and Port Authority® are trademarks of Lucent Technologies, Inc. All other marks are the property of their respective owners. Rev: 1G Page 1 of 1 Date 5/6/99 |