Re: (PM) Problem with OR-U to Max 1800

Thomas C Kinnen (tkinnen@lucentradius.com)
Tue, 21 Dec 1999 12:40:11 -0500

>Im having a prob with an OR-U bringing up the 2nd channel to a max-1800
that
>is configured with 8 bri's in a hunt group. Analog hunting works fine, but
>when the OR U tries to bring up a and channel, it always returns busy ont
he
>debug. Does this seem to indicate that the hunting is not set up right?
Keep
>in mind that voice calls to the bri # hunt fine. I have csd and csv all = 1
>on all spids of each bri.

Jake,

Check the telco. I've had a number claim they can hunt voice or data on a
BRI group but not both.

Tom

-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.
Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>