(PM) PM3 not assigning modems to analogue calls on a PRI.

Steve Burke (steve@pins.co.uk)
Sun, 19 Dec 1999 16:50:32 -0000

Hi all...

I have a single PM3 connected to 2 PRIs. It's been working fine
for about 2 years, but today it appears to have developed a
problem...

ISDN callers can successfully connect to either PRI (both
PRIs on a single hunt group number), but MODEM callers will
only connect if they happen to come in through the second
PRI.

If they happen to connect to the first PRI, they hear nothing,
no bleeps, just dead air. When this happens, a "sho modem" on
the PM3 shows a modem as "CONNECTING" but that's a far as it
ever gets...

So... it would seem that the PM3 isn't correctly assigning
modems to calls on the first PRI, but it's fine for calls
that come in on the second PRI.

And yes.. I have rebooted.

Any ideas ???

Best Regards... Steve
-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.
Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>