Re: (PM) Problem with port on PM3

Thomas C Kinnen (tkinnen@livingston.com)
Sun, 30 May 1999 12:00:19 -0700

Bill Ball wrote:
>
> I have one port, s2, that is not working. I recently had some problems
> with my Telco CT1 service and ever since port s2 has not been working. I've
> power cycled the unit as well as reset the port repeatedly. I've also
> re-installed OS 3.8 and I've backed up the port configuration from another
> working PM3 and restored it to this one. However no matter what I do I get
> the following when I do a show s2.

Try:

set s2 extended on

and see if you get the missing info.

-- 
Thomas C Kinnen - <tkinnen@ra.lucent.com> <tkinnen@sobhrach.com>
[RADIUS Test Engineer] - LUCENT Technologies RABU
"All of the opinions stated above are my own and not my employer's,
unless they were given to me by my employer"
-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.
Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>