:Unfortunately it is not possible to have 2 E1 PRI and a fractional E1 in a
:PM3, as Lucent decided not to manufacture a European version of the T1 card,
:available for the US market:(
Oh he wants 2 pri and 1 e1... I thought he wanted 1 of each.
:
:You can in theory have 1 PRI and one fractional E1 in a PM 3A 2E, However
:we, have come across clock source timing problems and have been unable to
:get this combination to work in some circumstances. Proceed with caution.
Hrm, it works in Texas at 1 location where we use 1 channel for a backhaul
t1, I guess YMMV. Woohoo, Ive never gotten to use that abbrev before!
~*-,._.,-*~'`^`'~*-,._.,-*~'`^`'~*-,._.,-*~'`^`'~*-,._.,-*~'`^`'~*-,._.,-*~
Jake Messinger, VP. ph:713-772-6690 Lucent Dealer
AMS, Inc. fx:713-774-3498 Medical Billing
8300 Bissonnet #400 jake@ams.com , ICQ# 4403734 Internet Services
Houston, Texas 77074 www.ams.com/~jake and Hardware
Adjunct Professor University of Houston, CBA jake@uh.edu
~*-,._.,-*~'`^`'~*-,._.,-*~'`^`'~*-,._.,-*~'`^`'~*-,._.,-*~'`^`'~*-,._.,-*~
INVENTOR OF the _.,-*~''~*-,._ SQUIGGLES (c) 1978
-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.
Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>