Did as you asked, attached to a port.
here's the response from an ISDN debug mode:
atd5721008S35: Sending Call Request - 5721008
S35: Received Proceeding
S35: Received Disconnect Incompatible Dest (B12 ID:8024)
S35: Sending Disconnect Request
S35: Received Clear Conf (B12 ID:8024)
S35: Redialing at alternate 64Kbps rate
S35: Sending Call Request - 5721008
S35: Received Proceeding
S35: Received Disconnect Incompatible Dest (B12 ID:8024)
S35: Sending Disconnect Request
NO CARRIER
S35: Received Clear Conf (B12 ID:8024)
I do have the ability to boot the netgear into a debug mode... have not done
it yet b ut certainly willing to do so.
Thanks!
-Scott
> -----Original Message-----
> From: owner-portmaster-users@livingston.com
> [mailto:owner-portmaster-users@livingston.com]On Behalf Of Thomas C
> Kinnen
> Sent: Monday, May 24, 1999 10:52 PM
> To: portmaster-users@livingston.com
> Subject: Re: (PM) Dialbacks - what do these messages indicate?
>
>
> "PmUser, Resident Lackey" wrote:
> >
> > Ahhhh, good point... the first message, which never made the
> list :/ had it.
> >
> > PM3 with PRI dialing to a BRI tied to a Netgear RT328 ISDN router.
>
> Here's a trick. Can you attach to a port and dial yourself on
> the PM? Also
> does the netgear have the equivalent of an ISDN debug and a PPP debug?
>
> --
> Thomas C Kinnen - <tkinnen@ra.lucent.com> <tkinnen@sobhrach.com>
> [RADIUS Test Engineer] - LUCENT Technologies RABU
> "All of the opinions stated above are my own and not my employer's,
> unless they were given to me by my employer"
> -
> To unsubscribe, email 'majordomo@livingston.com' with
> 'unsubscribe portmaster-users' in the body of the message.
> Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>
>
-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.