RE: (PM) RE: (Calculating Telephone Costs)

Andrea Campi (andrea@planet.it)
Wed, 19 May 1999 10:13:25 +0200

Hi!

> We're handeling the 'on demand' calls only like this:
[snip]

> The problem is, that the time difference between the incoming
> call and the dialback of the router should not be longer than a
> few seconds and the router didn't actual accept the call coming
> in, it has to react only on the D-Channel input. The two brand
> we've found acceptable are Zyxel (Prestige 128 or 100) or
> Shiwa-ISDN-Router, where the Shiva-Routers are not as stable as
> Zyxel.... It SHOULD work with Cisco (7xx, 100x) too, but we've
> never tested it.

The only problem we have with a similar setup is that ComOS doesn't know the
remote router is calling back, so it keeps retrying. Did you see anything
similar?

Bye,
Andrea

-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.
Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>