(PM) PM4 PRI : problem

MED, Wipro Systems, Inc ("Nair,)
Thu, 6 May 1999 14:04:24 -0500

My "sh line0" on PM4 shows as below,

---------------------- line0 - T1 Primary Rate ISDN ---------------

Status: UP Framing: ESF Encoding: B8ZS PCM: u-law

Receive Level: +2dB to -7.5dB
Clock Source: External

NFAS Not Configured
Alarms Violations
----------------------------- -----------------------------
Blue 0 Bipolar 0
Yellow 1 CRC Errors 0
Receive Carrier Loss 0 Multiframe Sync 0
Loss of Sync 0

I have connected the same PRI ckt which was working with PM3...

Why it is this "Yello 1" ... ?

When tried dialing out using attach and at&n0dt, it does not seems to be
working....

Help pls...

With Warm Regards
Shibu R
Senior Network Analyst
________________________________________________
Mailto : Shibu.Nair@med.ge.com
shibur@wipsys.soft.net
Tel : (414) 524 5261
Fax : (414) 896 2790

GE Medical Systems,
USA.

----------
From: Thomas C Kinnen[SMTP:tkinnen@livingston.com]
Reply To: Thomas C Kinnen
Sent: Wednesday, May 05, 1999 11:27 AM
To: 'portmaster-users@livingston.com'
Subject: Re: (PM) Couple of questions on PM3 ????

Mark E Larson wrote:

> >5)Does it support MSCHAP (Somebody already pointed this but
just
> >confirming)?
> Yes

No, CHAP yes, MSCHAP no.

> >8)Does it has a remote administration capacity for multiple
admin
> >accounts which are passwd protective?
>
> Yes, but only a single account can reboot the box
> (!root)

Ant Admininstrative user in RADIUS should be able to reboot the
box.

> >9)Does PM3 support redundancy in terms of powersupply
> Nope

If running -48V you can order it with Redundant power supplies.

--
Thomas C Kinnen - <tkinnen@ra.lucent.com> <tkinnen@sobhrach.com>
[RADIUS Test Engineer] - LUCENT Technologies RABU
"All of the opinions stated above are my own and not my
employer's,
unless they were given to me by my employer"
-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.
Searchable list archive:
<URL:http://www.livingston.com/Tech/archive/>

-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.