Re: (PM) Couple of questions on PM3 ????

Thomas C Kinnen (tkinnen@livingston.com)
Wed, 05 May 1999 09:27:42 -0700

Mark E Larson wrote:

> >5)Does it support MSCHAP (Somebody already pointed this but just
> >confirming)?
> Yes

No, CHAP yes, MSCHAP no.

> >8)Does it has a remote administration capacity for multiple admin
> >accounts which are passwd protective?
>
> Yes, but only a single account can reboot the box
> (!root)

Ant Admininstrative user in RADIUS should be able to reboot the box.

> >9)Does PM3 support redundancy in terms of powersupply
> Nope

If running -48V you can order it with Redundant power supplies.

-- 
Thomas C Kinnen - <tkinnen@ra.lucent.com> <tkinnen@sobhrach.com>
[RADIUS Test Engineer] - LUCENT Technologies RABU
"All of the opinions stated above are my own and not my employer's,
unless they were given to me by my employer"
-