+MS=56,1,28800,40000
just in case the modem is actually FLEX only, I only reccomend this because
maybe the user just upgraded the INF and didn't really upgrade the
firmware...
Otherwise try
+MS=V34
If that works it is a POS HCF...hope this helps...
Crawl
> From: Ely Lucas <ely@cmconline.com>
> Date: Tuesday, February 02, 1999 3:16 PM
>
>Hey everyone,
>
>Have a user using this modem and he can't connect. As soon as the handshake
>ends, it immediately begins retraining to different speeds. I see the
>speeds shift doing multiple show all commands and the show ses command shows
>the port at PPP. After about 30 seconds or so it disconnects him telling
>him to check his configuration. Bestdata.com says it uses a Rockwell
>chipset, but using +MS=12,1,28800,40000 makes the modem unresponsive.
>Anyone know whats going on with this computer?
-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.
Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>