(PM) PM3 Missing serial Port (fwd)

MegaZone (megazone@megazone.org)
Thu, 11 Jun 1998 10:16:47 -0700 (PDT)

Once upon a time Don Knott shaped the electrons to say...
>I noticed something strange on a PM3 the other day. When I do a "sh ses"
>command, all ports except S23 show up with their current status. If I do a
>"sh s23" for more detail I get this:

This is PRI I bet. The 24th channel is the D channel - so there is NO S23
when using PRI. Also no S48 with a second PRI. S23 and S48 only show up
when using CT1.

>I have opened a ticket with Livingston and they suggested that I open the
>unit and check all the connections. I've checked and haven't found

WHAT? Who told you to do that? Support, why would you want someone
poking around in a PM3, when all 's' ports are *logical* ports. There isn't
a wire for S23...

-MZ

-- 
<URL:mailto:megazone@megazone.org> Gweep, author, webmaster, human being, me
"A little nonsense now and then, is relished by the wisest men" 781-788-0130
<URL:mailto:megazone@gweep.net> <URL:http://www.megazone.org/> Hail Discordia!
-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.
Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>